Process Data Configuration
Click on ‘System Configuration’ in the left hand toolbar. WorkBench will now display the setup
screens for the MotiFlex’s Device Configuration File (DCF).
The initial screen shows our EPL Node ID (set via the rotary switches on the front of the MotiFlex
drive – in our example 02 hex) and the Modbus/TCP Node ID (the last Octet of our IP address),
which is set to the same value. If we’ve configured a MotiFlex in the past we have the option to
open a saved DCF file or we can choose to start a new configuration. We’ll select this option –
Start New Configuration. Click on Next to continue.